{"id":483,"date":"2015-08-30T03:21:57","date_gmt":"2015-08-30T03:21:57","guid":{"rendered":"http:\/\/www.heatsinkcalculator.com\/blog\/?p=483"},"modified":"2023-01-20T16:13:32","modified_gmt":"2023-01-20T16:13:32","slug":"how-to-design-a-flat-plate-heat-sink","status":"publish","type":"post","link":"https:\/\/www.heatsinkcalculator.com\/blog\/how-to-design-a-flat-plate-heat-sink\/","title":{"rendered":"How to design a flat plate heat sink"},"content":{"rendered":"<p>A heat sink is a part that conducts heat from a heat generating component to a larger surface area to dissipate the heat to the surroundings thus reducing the temperature of the component. Based on this definition anything from a rectangular sheet of metal to a complex finned copper or aluminum extrusion can be used as a heat sink. In situations where there is ample space and\/or the heat dissipated by the component is low an aluminum or copper plate can be used as an effective heat sink. The heat sink can be a simple plate or the metal wall of the enclosure housing the component as shown in figure 1.<\/p>\n<p><a href=\"http:\/\/www.heatsinkcalculator.com\/blog\/wp-content\/uploads\/2015\/08\/flat_plate_heatsink1.png\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-542\" src=\"http:\/\/www.heatsinkcalculator.com\/blog\/wp-content\/uploads\/2015\/08\/flat_plate_heatsink1.png\" alt=\"flat_plate_heatsink\" width=\"554\" height=\"250\" srcset=\"https:\/\/www.heatsinkcalculator.com\/blog\/wp-content\/uploads\/2015\/08\/flat_plate_heatsink1.png 554w, https:\/\/www.heatsinkcalculator.com\/blog\/wp-content\/uploads\/2015\/08\/flat_plate_heatsink1-300x135.png 300w\" sizes=\"auto, (max-width: 554px) 100vw, 554px\" \/><\/a>Figure 1. Flat plate heat sink dimensions<\/p>\n<p>To estimate the dimensions of the flat plate heat sink you need to determine the path of heat flowing to the surroundings and the magnitude to which that path resists the flow of heat. The thermal resistance circuit shown in figure 2 will be used to represent the path of heat flow. Let&#8217;s examine each of the thermal resistance elements:<\/p>\n<p><a href=\"http:\/\/www.heatsinkcalculator.com\/blog\/wp-content\/uploads\/2015\/08\/thermal_resistance_circuit.png\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-545\" src=\"http:\/\/www.heatsinkcalculator.com\/blog\/wp-content\/uploads\/2015\/08\/thermal_resistance_circuit.png\" alt=\"thermal_resistance_circuit\" width=\"489\" height=\"145\" srcset=\"https:\/\/www.heatsinkcalculator.com\/blog\/wp-content\/uploads\/2015\/08\/thermal_resistance_circuit.png 489w, https:\/\/www.heatsinkcalculator.com\/blog\/wp-content\/uploads\/2015\/08\/thermal_resistance_circuit-300x89.png 300w\" sizes=\"auto, (max-width: 489px) 100vw, 489px\" \/><\/a><\/p>\n<p>Figure 2. Thermal resistance circuit of a flat plate heat sink<br \/>\n<!--more continue&gt;&gt;--><br \/>\n<span style=\"font-size: 16pt;\"><strong>Junction to case resistance<br \/>\n<\/strong><\/span>The junction to case thermal resistance (R<sub>th-jc<\/sub>) is the thermal resistance from the operating portion of a semiconductor device to the outside surface of the package (case) where the heat sink will be attached. The case temperature is considered to be at a constant temperature across the attachment surface.\u00a0 R<sub>th-jc<\/sub> is a measured value typically provided by the device manufacturers and specified in the data sheet for the device.<strong><br \/>\n<\/strong><\/p>\n<p><strong><br \/>\n<span style=\"font-size: 16pt;\">Contact and thermal Interface resistance<br \/>\n<\/span><\/strong>The thermal contact resistance (R<sub>cont<\/sub>) is the thermal resistance between the case and the heat sink. Because of imperfections in the surface of the case and heat sink the actual contact area is smaller than the apparent contact area as shown in figure 3. Mathematical models have been proposed to calculate R<sub>cont<\/sub> that are based on the contact pressure, material surface roughness and material hardness. These models can be quite complicated and the material surface and hardness information may be difficult to obtain. Typically\u00a0 R<sub>cont<\/sub> is determined based on experimental data and past experience.<\/p>\n<p>In order to reduce the influence of R<sub>cont <\/sub>interface materials that fill the gaps between the case and the heat sink are used. These materials come in the form of special thermal greases, filler compounds, phase changing thermal pads and thermal tapes. The thermal conductivity of these materials range between 0.5 W\/m-K to 4 W\/m-K. With the gap between the two mating surfaces filled with the thermal interface material the thermal resistance across the case and the heat sink is now a function of the interface material thickness, thermal conductivity and surface area given by equation 1.<\/p>\n<p><span style=\"display: inline-block; width: 500px;\"><img src='http:\/\/s.wordpress.com\/latex.php?latex=%5Cdisplaystyle%20R_%7Bint%7D%3D%5Cfrac%7Bt%7D%7BkA%7D&bg=ffffff&fg=000000&s=0' alt='Latex formula' title='Latex formula' class='latex' \/><\/span>1<br \/>\nwhere:<br \/>\n<span style=\"display: inline-block; width: 140px;\"><img src='http:\/\/s.wordpress.com\/latex.php?latex=%5Cdisplaystyle%20t&bg=ffffff&fg=000000&s=0' alt='Latex formula' title='Latex formula' class='latex' \/><\/span>is the thermal interface material thickness<br \/>\n<span style=\"display: inline-block; width: 140px;\"><img src='http:\/\/s.wordpress.com\/latex.php?latex=%5Cdisplaystyle%20k&bg=ffffff&fg=000000&s=0' alt='Latex formula' title='Latex formula' class='latex' \/><\/span>is the thermal interface material thermal conductivity<br \/>\n<span style=\"display: inline-block; width: 140px;\"><img src='http:\/\/s.wordpress.com\/latex.php?latex=%5Cdisplaystyle%20A&bg=ffffff&fg=000000&s=0' alt='Latex formula' title='Latex formula' class='latex' \/><\/span>is the apparent contact area of the case<\/p>\n<p>Note for many thermal interface materials the thermal conductivity varies with clamping pressure. The manufacturer will typically provide these data in the product specification sheets.<\/p>\n<p><strong><a href=\"http:\/\/www.heatsinkcalculator.com\/blog\/wp-content\/uploads\/2015\/08\/contact_resistance.png\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-546\" src=\"http:\/\/www.heatsinkcalculator.com\/blog\/wp-content\/uploads\/2015\/08\/contact_resistance.png\" alt=\"contact_resistance\" width=\"536\" height=\"95\" srcset=\"https:\/\/www.heatsinkcalculator.com\/blog\/wp-content\/uploads\/2015\/08\/contact_resistance.png 536w, https:\/\/www.heatsinkcalculator.com\/blog\/wp-content\/uploads\/2015\/08\/contact_resistance-300x53.png 300w\" sizes=\"auto, (max-width: 536px) 100vw, 536px\" \/><\/a><\/strong><\/p>\n<p>Figure 3. Contact, interface and junction to case resistances<\/p>\n<p><strong><br \/>\n<span style=\"font-size: 16pt;\">Thermal spreading resistance<br \/>\n<\/span><\/strong>The thermal spreading resistance (R<sub>sp<\/sub>) is a result of heat flowing via conduction between the contact area of the case on the\u00a0 surface of the flat plate and the larger heat dissipating surface area of the flat plate.\u00a0 Closed form equations for R<sub>sp<\/sub> were develop by Lee et al [1]. These equations provide a very close approximation to the exact solution which will not be discussed here because of the complexity of the calculations required.<\/p>\n<p>The first step in using Lee&#8217;s equations is to convert the dimensions of the two interacting rectangular surfaces into equivalent radii\u00a0 using equations 2 and 3.<\/p>\n<p><span style=\"display: inline-block; width: 500px;\"><img src='http:\/\/s.wordpress.com\/latex.php?latex=%5Cdisplaystyle%20r_%7B1%7D%3D%5Csqrt%7B%5Cfrac%7BL_%7Bs%7DW_%7Bs%7D%7D%7B%5Cpi%20%7D%7D&bg=ffffff&fg=000000&s=0' alt='Latex formula' title='Latex formula' class='latex' \/><\/span>2<\/p>\n<p><span style=\"display: inline-block; width: 500px;\"><img src='http:\/\/s.wordpress.com\/latex.php?latex=%5Cdisplaystyle%20r_%7B2%7D%3D%5Csqrt%7B%5Cfrac%7BLW%7D%7B%5Cpi%20%7D%7D&bg=ffffff&fg=000000&s=0' alt='Latex formula' title='Latex formula' class='latex' \/><\/span>3<\/p>\n<p>R<sub>sp<\/sub> can then be calculated using the following equations:<\/p>\n<p><span style=\"display: inline-block; width: 500px;\"><img src='http:\/\/s.wordpress.com\/latex.php?latex=%5Cdisplaystyle%20%5Cvarepsilon%20%3Dr_%7B1%7D%2Fr_%7B2%7D&bg=ffffff&fg=000000&s=0' alt='Latex formula' title='Latex formula' class='latex' \/><\/span>4<\/p>\n<p><span style=\"display: inline-block; width: 500px;\"><img src='http:\/\/s.wordpress.com\/latex.php?latex=%5Cdisplaystyle%20%5Ctau%20%3Dt_%7Bp%7D%2Fr_%7B2%7D&bg=ffffff&fg=000000&s=0' alt='Latex formula' title='Latex formula' class='latex' \/><\/span>5<\/p>\n<p><span style=\"display: inline-block; width: 500px;\"><img src='http:\/\/s.wordpress.com\/latex.php?latex=%5Cdisplaystyle%20Bi%3D%5Cfrac%7Bh_%7Beff%7D%5Ctimes%20r_%7B2%7D%7D%7Bk%7D&bg=ffffff&fg=000000&s=0' alt='Latex formula' title='Latex formula' class='latex' \/><\/span>6<\/p>\n<p>where:<br \/>\n<span style=\"display: inline-block; width: 140px;\"><img src='http:\/\/s.wordpress.com\/latex.php?latex=%5Cdisplaystyle%20h_%7Beff%7D&bg=ffffff&fg=000000&s=0' alt='Latex formula' title='Latex formula' class='latex' \/><\/span>is the effective convection coefficient of the flat plate<\/p>\n<p>See equation 18 for the calculation of h<sub>eff<\/sub>.<\/p>\n<p><span style=\"display: inline-block; width: 140px;\"><img src='http:\/\/s.wordpress.com\/latex.php?latex=%5Cdisplaystyle%20k_%7Bp%7D&bg=ffffff&fg=000000&s=0' alt='Latex formula' title='Latex formula' class='latex' \/><\/span>is the thermal conductivity of the flat plate<\/p>\n<p><span style=\"display: inline-block; width: 500px;\"><img src='http:\/\/s.wordpress.com\/latex.php?latex=%5Cdisplaystyle%20%5Clambda%20%3D%5Cpi%20%2B%5Cfrac%7B1%7D%7B%5Cvarepsilon%20%5Csqrt%7B%5Cpi%20%7D%7D&bg=ffffff&fg=000000&s=0' alt='Latex formula' title='Latex formula' class='latex' \/><\/span>7<\/p>\n<p><span style=\"display: inline-block; width: 500px;\"><img src='http:\/\/s.wordpress.com\/latex.php?latex=%5Cdisplaystyle%20%5Cphi%20%3D%5Cfrac%7Btanh%28%5Clambda%20%5Ctimes%20%5Ctau%20%29%2B%5Cfrac%7B%5Clambda%20%7D%7BBi%7D%7D%7B1%2B%5Cfrac%7B%5Clambda%20%7D%7BBi%7Dtanh%28%5Clambda%20%5Ctimes%20%5Ctau%20%29%7D&bg=ffffff&fg=000000&s=0' alt='Latex formula' title='Latex formula' class='latex' \/><\/span>8<\/p>\n<p><span style=\"display: inline-block; width: 500px;\"><img src='http:\/\/s.wordpress.com\/latex.php?latex=%5Cdisplaystyle%20%5CPsi_%7Bmax%7D%3D%5Cfrac%7B%5Cvarepsilon%20%5Ctimes%20%5Ctau%20%7D%7B%5Csqrt%7B%5Cpi%20%7D%7D%2B%5Cfrac%7B%281-%5Cvarepsilon%20%29%5Cphi%20%7D%7B%5Csqrt%7B%5Cpi%20%7D%7D&bg=ffffff&fg=000000&s=0' alt='Latex formula' title='Latex formula' class='latex' \/><\/span>9<\/p>\n<p><span style=\"display: inline-block; width: 500px;\"><img src='http:\/\/s.wordpress.com\/latex.php?latex=%5Cdisplaystyle%20R_%7Bsp%7D%3D%5Cfrac%7B%5CPsi%20_%7Bmax%7D%7D%7Bk_%7Bp%7D%5Ctimes%20r_%7B1%7D%5Csqrt%7B%5Cpi%20%7D%7D&bg=ffffff&fg=000000&s=0' alt='Latex formula' title='Latex formula' class='latex' \/><\/span>10<\/p>\n<p><strong><span style=\"font-size: 16pt;\">Convection thermal resistance<br \/>\n<\/span><\/strong>The convection thermal resistance factors in how well heat is removed from the surface of the plate via the movement of air. The dimensionless Nusselt number [2] for a heated vertical flat plate undergoing natural convection is given by equation 11. The Nusselt number is a dimensionless variable used in convection calculations.<\/p>\n<p><span style=\"display: inline-block; width: 500px;\"><img src='http:\/\/s.wordpress.com\/latex.php?latex=%5Cdisplaystyle%20%5Coverline%7BNu_%7BL%7D%7D%3D0.59Ra_%7BL%7D%5E%7B0.25%7D&bg=ffffff&fg=000000&s=0' alt='Latex formula' title='Latex formula' class='latex' \/><\/span>11<\/p>\n<p>where:<\/p>\n<p><span style=\"display: inline-block; width: 500px;\"><img src='http:\/\/s.wordpress.com\/latex.php?latex=%5Cdisplaystyle%20Ra_%7BL%7D%3D%5Cfrac%7Bg%5Cbeta%20%28T_%7Bs%7D-T_%7Bamb%7D%29L%5E%7B3%7D%7D%7B%5Cnu%20%5Calpha%20%7D&bg=ffffff&fg=000000&s=0' alt='Latex formula' title='Latex formula' class='latex' \/><\/span>12<\/p>\n<p><span style=\"display: inline-block; width: 140px;\"><img src='http:\/\/s.wordpress.com\/latex.php?latex=%5Cdisplaystyle%20%5Cbeta&bg=ffffff&fg=000000&s=0' alt='Latex formula' title='Latex formula' class='latex' \/><\/span>is the thermal coefficient of expansion (1\/T<sub>avg<\/sub>) in units K<sup>-1<\/sup><\/p>\n<p><span style=\"display: inline-block; width: 140px;\"><img src='http:\/\/s.wordpress.com\/latex.php?latex=%5Cdisplaystyle%20T_%7Bs%7D&bg=ffffff&fg=000000&s=0' alt='Latex formula' title='Latex formula' class='latex' \/><\/span>is the surface temperature of the plate<\/p>\n<p><span style=\"display: inline-block; width: 140px;\"><img src='http:\/\/s.wordpress.com\/latex.php?latex=%5Cdisplaystyle%20T_%7Bamb%7D&bg=ffffff&fg=000000&s=0' alt='Latex formula' title='Latex formula' class='latex' \/><\/span>is the ambient air temperature<\/p>\n<p><span style=\"display: inline-block; width: 140px;\"><img src='http:\/\/s.wordpress.com\/latex.php?latex=%5Cdisplaystyle%20g&bg=ffffff&fg=000000&s=0' alt='Latex formula' title='Latex formula' class='latex' \/><\/span>acceleration due to gravity<\/p>\n<p><span style=\"display: inline-block; width: 500px;\"><img src='http:\/\/s.wordpress.com\/latex.php?latex=%5Cdisplaystyle%20T_%7Bavg%7D%3D%28T_%7Bs%7D%2BT_%7Bamb%7D%29%2F2&bg=ffffff&fg=000000&s=0' alt='Latex formula' title='Latex formula' class='latex' \/><\/span>13<\/p>\n<p><span style=\"display: inline-block; width: 140px;\"><img src='http:\/\/s.wordpress.com\/latex.php?latex=%5Cdisplaystyle%20%5Cnu&bg=ffffff&fg=000000&s=0' alt='Latex formula' title='Latex formula' class='latex' \/><\/span>is the kinematic viscosity of air evaluated at T<sub>avg<\/sub><\/p>\n<p><span style=\"display: inline-block; width: 140px;\"><img src='http:\/\/s.wordpress.com\/latex.php?latex=%5Cdisplaystyle%20%5Calpha&bg=ffffff&fg=000000&s=0' alt='Latex formula' title='Latex formula' class='latex' \/><\/span>is the thermal diffusivity of air evaluated at T<sub>avg<\/sub><\/p>\n<p>The average convection coefficient is calculated with equation 14. The convection thermal resistance R<sub>conv<\/sub> is a function of the plate surface area A<sub>p<\/sub> and the average convection coefficient and is calculated using equation 15. Note the plate surface area does not include the area resulting from the plate thickness since this is considered much much smaller than the front and back surface areas.<\/p>\n<p><span style=\"display: inline-block; width: 500px;\"><img src='http:\/\/s.wordpress.com\/latex.php?latex=%5Cdisplaystyle%20%5Coverline%7Bh%7D%3D%5Coverline%7BNu%7D_%7BL%7D%5Ctimes%20k_%7Bair%7D%2FL&bg=ffffff&fg=000000&s=0' alt='Latex formula' title='Latex formula' class='latex' \/><\/span>14<\/p>\n<p>where:<\/p>\n<p><span style=\"display: inline-block; width: 140px;\"><img src='http:\/\/s.wordpress.com\/latex.php?latex=%5Cdisplaystyle%20k_%7Bair%7D&bg=ffffff&fg=000000&s=0' alt='Latex formula' title='Latex formula' class='latex' \/><\/span>is the thermal conductivity of air evaluated at T<sub>avg<\/sub><\/p>\n<p><span style=\"display: inline-block; width: 500px;\"><img src='http:\/\/s.wordpress.com\/latex.php?latex=%5Cdisplaystyle%20R_%7Bconv%7D%3D%5Cfrac%7B1%7D%7B%5Coverline%7Bh%7DA_%7Bp%7D%7D&bg=ffffff&fg=000000&s=0' alt='Latex formula' title='Latex formula' class='latex' \/><\/span>15<\/p>\n<p><strong><span style=\"font-size: 16pt;\">Radiation thermal resistance<br \/>\n<\/span><\/strong>The thermal resistance due to radiation is given by equation 16.<\/p>\n<p><span style=\"display: inline-block; width: 500px;\"><img src='http:\/\/s.wordpress.com\/latex.php?latex=%5Cdisplaystyle%20R_%7Brad%7D%3D%5Cfrac%7B1%7D%7Bh_%7Br%7DA_%7Bp%7D%7D&bg=ffffff&fg=000000&s=0' alt='Latex formula' title='Latex formula' class='latex' \/><\/span>16<\/p>\n<p>where:<\/p>\n<p><span style=\"display: inline-block; width: 500px;\"><img src='http:\/\/s.wordpress.com\/latex.php?latex=%5Cdisplaystyle%20h_%7Br%7D%3D%5Cvarepsilon%20%5Csigma%20%28T_%7Bs%7D%2BT_%7Bamb%7D%29%28T_%7Bs%7D%5E%7B2%7D%2BT_%7Bamb%7D%5E%7B2%7D%29&bg=ffffff&fg=000000&s=0' alt='Latex formula' title='Latex formula' class='latex' \/><\/span>15<\/p>\n<p><span style=\"display: inline-block; width: 140px;\"><img src='http:\/\/s.wordpress.com\/latex.php?latex=%5Cdisplaystyle%20%5Cvarepsilon&bg=ffffff&fg=000000&s=0' alt='Latex formula' title='Latex formula' class='latex' \/><\/span>is the emissivity of the surface of the flat plate<\/p>\n<p><img src='http:\/\/s.wordpress.com\/latex.php?latex=%5Cdisplaystyle%5Csigma%3D5.67%5Ctimes%2010%5E%7B-8%7DW%2Fm%5E%7B2%7D%5Ccdot%20K%5E%7B4%7D&bg=ffffff&fg=000000&s=0' alt='Latex formula' title='Latex formula' class='latex' \/> (<em>Stefan-Boltzman constant<\/em>)<\/p>\n<p>It is assumed that the plate is radiating heat to a much larger surrounding surface as such the surroundings can be considered an ideal radiator or blackbody. In certain situations, the temperature of the surrounding surface may be different than the ambient air temperature. In these cases, T<sub>amb<\/sub> should be replaced with the temperature of the surrounding surface in equation 15.<\/p>\n<p>The effective convection coefficient h<sub>eff<\/sub> used to calculate the thermal spreading resistance is given by equation 18.<\/p>\n<p><span style=\"display: inline-block; width: 500px;\"><img src='http:\/\/s.wordpress.com\/latex.php?latex=%5Cdisplaystyle%20h_%7Beff%7D%3D%5Coverline%7Bh%7D%2Bh_%7Br%7D&bg=ffffff&fg=000000&s=0' alt='Latex formula' title='Latex formula' class='latex' \/><\/span>18<\/p>\n<p>The values of R<sub>rad<\/sub>, R<sub>conv<\/sub> and R<sub>sp<\/sub> cannot be directly solved for since they are functions of T<sub>s<\/sub> the surface temperature of the plate. Assuming that all the heat generated by the heat source is being dissipated by the flat plate the equation defining this energy balance is given by equation 19.<\/p>\n<p><span style=\"display: inline-block; width: 500px;\"><img src='http:\/\/s.wordpress.com\/latex.php?latex=%5Cdisplaystyle%20%5Cfrac%7BR_%7Brad%7D%2BR_%7Bconv%7D%7D%7BR_%7Brad%7DR_%7Bconv%7D%7D%28T_%7Bs%7D-T_%7Bamb%7D%29-%5Cdot%7BQ%7D%3D0&bg=ffffff&fg=000000&s=0' alt='Latex formula' title='Latex formula' class='latex' \/><\/span>19<\/p>\n<p>where:<br \/>\n<span style=\"display: inline-block; width: 140px;\"><img src='http:\/\/s.wordpress.com\/latex.php?latex=%5Cdisplaystyle%20%5Cdot%7BQ%7D&bg=ffffff&fg=000000&s=0' alt='Latex formula' title='Latex formula' class='latex' \/><\/span>is the heat generated by the heat source<\/p>\n<p>T<sub>s<\/sub> can be calculated using a numerical solver available in most mathematical software or the &#8220;Goal Seek&#8221; function in Excel.<\/p>\n<p>With all the thermal resistances known the thermal circuit shown in figure 2 can be reduced to a single junction to ambient resistance R<sub>j-a<\/sub> using equation 20.<\/p>\n<p><span style=\"display: inline-block; width: 500px;\"><img src='http:\/\/s.wordpress.com\/latex.php?latex=%5Cdisplaystyle%20R_%7Bj-a%7D%3DR_%7Bth-jc%7D%2BR_%7Bint%7D%2BR_%7Bsp%7D%2B%5Cfrac%7BR_%7Brad%7DR_%7Bconv%7D%7D%7BR_%7Brad%7D%2BR_%7Bconv%7D%7D&bg=ffffff&fg=000000&s=0' alt='Latex formula' title='Latex formula' class='latex' \/><\/span>20<\/p>\n<p>Finally using equation 21 the junction or heat source temperature can be obtained.<\/p>\n<p><span style=\"display: inline-block; width: 500px;\"><img src='http:\/\/s.wordpress.com\/latex.php?latex=%5Cdisplaystyle%20T_%7Bj%7D%3DR_%7Bj-a%7D%5Cdot%7BQ%7D%2BT_%7Bamb%7D&bg=ffffff&fg=000000&s=0' alt='Latex formula' title='Latex formula' class='latex' \/><\/span>21<\/p>\n<div style=\"background-color: #ffff99; padding: 7px;\">\n<p style=\"margin: 0px;\">An online heat sink calculator based on the calculation methodology described in this blog post is available free of cost. Click the following link to access the calculator: <a href=\"https:\/\/www.heatsinkcalculator.com\/flat-plate-heat-sink-calculator.html\">Flat Plate Heat Sink Calculator<\/a><\/p>\n<\/div>\n<p><span style=\"text-decoration: underline;\">References:<\/span><br \/>\n[1] S. Lee, S. Song, V. Au, and K.P. Moran, \u201cConstriction\/Spreading Resistance Model for Electronic Packaging,\u201d in: Proceedings of ASME\/JSME Engineering Conference, Vol. 4, 1995<\/p>\n<p>[2] F. <span class=\"reference-text\"><span class=\"citation book\">Incropera, D. DeWitt,\u00a0 (1990). <i>Fundamentals of Heat and Mass Transfer<\/i> (3rd ed.). Hoboken: Wiley. pp. 542<\/span><\/span><\/p>\n","protected":false},"excerpt":{"rendered":"<p>A heat sink is a part that conducts heat from a heat generating component to a larger surface area to [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[1],"tags":[],"class_list":["post-483","post","type-post","status-publish","format-standard","hentry","category-uncategorized"],"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/www.heatsinkcalculator.com\/blog\/wp-json\/wp\/v2\/posts\/483","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.heatsinkcalculator.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.heatsinkcalculator.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.heatsinkcalculator.com\/blog\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.heatsinkcalculator.com\/blog\/wp-json\/wp\/v2\/comments?post=483"}],"version-history":[{"count":101,"href":"https:\/\/www.heatsinkcalculator.com\/blog\/wp-json\/wp\/v2\/posts\/483\/revisions"}],"predecessor-version":[{"id":1567,"href":"https:\/\/www.heatsinkcalculator.com\/blog\/wp-json\/wp\/v2\/posts\/483\/revisions\/1567"}],"wp:attachment":[{"href":"https:\/\/www.heatsinkcalculator.com\/blog\/wp-json\/wp\/v2\/media?parent=483"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.heatsinkcalculator.com\/blog\/wp-json\/wp\/v2\/categories?post=483"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.heatsinkcalculator.com\/blog\/wp-json\/wp\/v2\/tags?post=483"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}