{"id":737,"date":"2016-08-30T14:48:01","date_gmt":"2016-08-30T14:48:01","guid":{"rendered":"http:\/\/www.heatsinkcalculator.com\/blog\/?p=737"},"modified":"2018-05-23T20:06:01","modified_gmt":"2018-05-23T20:06:01","slug":"how-to-calculate-the-temperature-in-a-ventilated-electronics-enclosure","status":"publish","type":"post","link":"https:\/\/www.heatsinkcalculator.com\/blog\/how-to-calculate-the-temperature-in-a-ventilated-electronics-enclosure\/","title":{"rendered":"How to calculate the temperature in a ventilated electronics enclosure"},"content":{"rendered":"<p>Electrical and electronic components are sometimes housed in enclosures with ventilation openings to allow ambient air into the enclosure to more efficiently cool heat generating components.\u00a0The most common ventilation configuration is to have openings at the top and bottom of the enclosure as shown in figure 1.<\/p>\n<p>&nbsp;<\/p>\n<p><a href=\"http:\/\/www.heatsinkcalculator.com\/blog\/wp-content\/uploads\/2016\/08\/ventilated_enclosure_natural_convection.png\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-801\" src=\"http:\/\/www.heatsinkcalculator.com\/blog\/wp-content\/uploads\/2016\/08\/ventilated_enclosure_natural_convection.png\" alt=\"ventilated enclosure in natural convection\" width=\"431\" height=\"324\" srcset=\"https:\/\/www.heatsinkcalculator.com\/blog\/wp-content\/uploads\/2016\/08\/ventilated_enclosure_natural_convection.png 431w, https:\/\/www.heatsinkcalculator.com\/blog\/wp-content\/uploads\/2016\/08\/ventilated_enclosure_natural_convection-300x226.png 300w\" sizes=\"auto, (max-width: 431px) 100vw, 431px\" \/><\/a><\/p>\n<p>Figure 1. Ventilated enclosure cooled via natural convection<\/p>\n<p>The air flow through the enclosure is driven by the difference in air density of the cooler air outside the enclosure and warmer air inside due to the heat transferred from the heat generating components. As the air flows vertically through the lower ventilation openings and across the heat generating components its temperature increases. As a result components mounted at higher locations in the enclosure will be subjected to air temperatures above the ambient air temperature. Determining the internal air temperature surrounding these components\u00a0will allow you to identify and relocate components that have a maximum ambient operating temperature lower than the surrounding air temperature. The\u00a0size or number of the ventilation openings can also be adjusted to lower the internal ambient temperature.<br \/>\n<!--more continue&gt;&gt;--><br \/>\nIf detailed thermal analysis needs to be conducted on components that have attached\u00a0heat sinks, the heat sink can be modeled as if it were sitting in open air and the calculated internal air temperature at the heat sink location can be used as the ambient temperature.<\/p>\n<p>As the air flows into, through and out of the enclosure the flow restrictions caused by the inlet ventilation openings, internal components and outlet ventilation openings produce a corresponding pressure drop denoted by \u0394P<sub>inlet<\/sub>, \u0394P<sub>comp<\/sub> and \u0394P<sub>outlet<\/sub> respectively.<\/p>\n<p>The difference in density between air flowing into the enclosure and that exiting the enclosure produces a pressure difference \u0394P<sub>bouyancy<\/sub>. This pressure difference must be balanced by the sum of the pressure drops through the enclosure as expressed in equation 1.<\/p>\n<p><span style=\"display: inline-block; width: 500px;\"><img src='http:\/\/s.wordpress.com\/latex.php?latex=%5Cdisplaystyle%20%5CDelta%20P_%7Binlet%7D%2B%5CDelta%20P_%7Bcomp%7D%2B%5CDelta%20P_%7Boutlet%7D-%5CDelta%20P_%7Bbouyancy%7D%3D0&bg=ffffff&fg=000000&s=0' alt='Latex formula' title='Latex formula' class='latex' \/><\/span>1<\/p>\n<p>where:<br \/>\n<span style=\"display: inline-block; width: 500px;\"><img src='http:\/\/s.wordpress.com\/latex.php?latex=%5Cdisplaystyle%20%5CDelta%20P_%7Bbouyancy%7D%3D%5Cleft%20%28%5Crho_%7B%5Cinfty%20%7D-%5Coverline%7B%5Crho%7D_%7Bint%7D%20%5Cright%20%29gh&bg=ffffff&fg=000000&s=0' alt='Latex formula' title='Latex formula' class='latex' \/><\/span>2<\/p>\n<p><span style=\"display: inline-block; width: 140px;\"><img src='http:\/\/s.wordpress.com\/latex.php?latex=%5Cdisplaystyle%20%5Crho_%7B%5Cinfty%7D&bg=ffffff&fg=000000&s=0' alt='Latex formula' title='Latex formula' class='latex' \/><\/span>density of the ambient air<br \/>\n<span style=\"display: inline-block; width: 140px;\"><img src='http:\/\/s.wordpress.com\/latex.php?latex=%5Cdisplaystyle%20%5Coverline%7B%5Crho%7D_%7Bint%7D&bg=ffffff&fg=000000&s=0' alt='Latex formula' title='Latex formula' class='latex' \/><\/span>average density of the air in the enclosure<br \/>\n<span style=\"display: inline-block; width: 140px;\"><img src='http:\/\/s.wordpress.com\/latex.php?latex=%5Cdisplaystyle%20g&bg=ffffff&fg=000000&s=0' alt='Latex formula' title='Latex formula' class='latex' \/><\/span>acceleration due to gravity<br \/>\n<span style=\"display: inline-block; width: 140px;\"><img src='http:\/\/s.wordpress.com\/latex.php?latex=%5Cdisplaystyle%20h&bg=ffffff&fg=000000&s=0' alt='Latex formula' title='Latex formula' class='latex' \/><\/span>vertical distance between the bottom of the heat sources and the outlet ventilation openings (see figure 1)<\/p>\n<p>The average density of the air inside the enclosure can be approximated using equation 3.<\/p>\n<p><span style=\"display: inline-block; width: 500px;\"><img src='http:\/\/s.wordpress.com\/latex.php?latex=%5Cdisplaystyle%20%5Coverline%7B%5Crho%20%7D_%7Bint%7D%3D%5Crho%20_%7B%5Cinfty%20%7D%5Cleft%20%5B%201-%5Cbeta%20%5Cleft%20%28%20%5Coverline%7BT%7D_%7Bint%7D-T_%7B%5Cinfty%20%7D%20%5Cright%20%29%20%5Cright%20%5D&bg=ffffff&fg=000000&s=0' alt='Latex formula' title='Latex formula' class='latex' \/><\/span>3<\/p>\n<p>where:<br \/>\n<span style=\"display: inline-block; width: 140px;\"><img src='http:\/\/s.wordpress.com\/latex.php?latex=%5Cdisplaystyle%20%5Cbeta&bg=ffffff&fg=000000&s=0' alt='Latex formula' title='Latex formula' class='latex' \/><\/span>thermal expansion coefficient of air at T<sub>\u221e<\/sub><br \/>\n<span style=\"display: inline-block; width: 140px;\"><img src='http:\/\/s.wordpress.com\/latex.php?latex=%5Cdisplaystyle%20%5Coverline%7BT%7D_%7Bint%7D&bg=ffffff&fg=000000&s=0' alt='Latex formula' title='Latex formula' class='latex' \/><\/span>average air temperature in the enclosure<\/p>\n<p>Substituting equation 3 into 2 produces equation 4 that relates the average internal and ambient air temperatures to the pressure difference due to the change in air temperature.<\/p>\n<p><span style=\"display: inline-block; width: 500px;\"><img src='http:\/\/s.wordpress.com\/latex.php?latex=%5Cdisplaystyle%20%5CDelta%20P_%7Bbouyancy%7D%3D%5Crho%20_%7B%5Cinfty%20%7D%5Cbeta%20%5Cleft%20%28%20%5Coverline%7BT%7D_%7Bint%7D-T_%7B%5Cinfty%7D%20%5Cright%29gh&bg=ffffff&fg=000000&s=0' alt='Latex formula' title='Latex formula' class='latex' \/><\/span>4<\/p>\n<p>The pressure drop due to the inlet and outlet ventilation openings (equation 5) is related to the speed of the airflow through the openings and the number of and size of each opening. A representation of a typical ventilation openings is shown in figure 2.<\/p>\n<p><span style=\"display: inline-block; width: 500px;\"><img src='http:\/\/s.wordpress.com\/latex.php?latex=%5Cdisplaystyle%20%5CDelta%20P_%7Binlet%2Foutlet%7D%3Dk%5Crho%20_%7B%5Cinfty%20%7D%5Cfrac%7BU%5E%7B2%7D%7D%7B2%7D&bg=ffffff&fg=000000&s=0' alt='Latex formula' title='Latex formula' class='latex' \/><\/span>5<\/p>\n<p><span style=\"display: inline-block; width: 140px;\"><img src='http:\/\/s.wordpress.com\/latex.php?latex=%5Cdisplaystyle%20U&bg=ffffff&fg=000000&s=0' alt='Latex formula' title='Latex formula' class='latex' \/><\/span>is the air speed through each ventilation opening<br \/>\n<span style=\"display: inline-block; width: 140px;\"><img src='http:\/\/s.wordpress.com\/latex.php?latex=%5Cdisplaystyle%20k&bg=ffffff&fg=000000&s=0' alt='Latex formula' title='Latex formula' class='latex' \/><\/span>is the fluid resistance coefficient<\/p>\n<p><a href=\"http:\/\/www.heatsinkcalculator.com\/blog\/wp-content\/uploads\/2014\/08\/ventilation_opening.png\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-191 aligncenter\" src=\"http:\/\/www.heatsinkcalculator.com\/blog\/wp-content\/uploads\/2014\/08\/ventilation_opening.png\" alt=\"ventilation openings\" width=\"217\" height=\"158\" \/><\/a>Figure 2. Ventilation openings<\/p>\n<p>The calculation for the fluid resistance coefficient, k is the same as that used in the blog article\u00a0<a href=\"http:\/\/www.heatsinkcalculator.com\/blog\/estimating-forced-convection-cooled-heat-sink-performance-in-a-ventilated-enclosure-part-1\/\">Estimating Forced Convection Cooled Heat Sink Performance in a Ventilated Enclosure (Part 1)<\/a>. It will be repeated here for convenience.<\/p>\n<p>for Re&gt;10<sup>5<\/sup><br \/>\n<span style=\"display: inline-block; width: 500px;\"><img src='http:\/\/s.wordpress.com\/latex.php?latex=%5Cdisplaystyle%20k%3D%20%5Cleft%20%5B%200.707%5Cleft%281-%5Cfrac%7BA_%7B1%7D%7D%7BA_%7B_%7B0%7D%7D%7D%5Cright%20%29%5E%7B0.5%7D%2B%5Cleft%281-%5Cfrac%7BA_%7B1%7D%7D%7BA_%7B0%7D%7D%5Cright%29%5Cright%20%5D%5E%7B2%7D%5Cleft%28%5Cfrac%7BA_%7B0%7D%7D%7BA_%7B1%7D%7D%20%5Cright%29%5E%7B2%7D&bg=ffffff&fg=000000&s=0' alt='Latex formula' title='Latex formula' class='latex' \/><\/span>6<\/p>\n<p>for 30&lt;Re&lt;10<sup>5<\/sup><br \/>\n<span style=\"display: inline-block; width: 500px;\"><img src='http:\/\/s.wordpress.com\/latex.php?latex=%5Cdisplaystyle%20k%3D%5Cleft%20%28%2033%2FRe%20%5Cright%20%29%5Cleft%20%28%20%5Cfrac%7BA_%7B_%7B0%7D%7D%7D%7BA_%7B_%7B1%7D%7D%7D%20%5Cright%20%29%5E%7B2%7D%2B%5Cvarepsilon%20%5Cvarphi&bg=ffffff&fg=000000&s=0' alt='Latex formula' title='Latex formula' class='latex' \/><\/span>7<\/p>\n<p>for Re&lt;30<br \/>\n<span style=\"display: inline-block; width: 500px;\"><img src='http:\/\/s.wordpress.com\/latex.php?latex=%5Cdisplaystyle%20k%3D%5Cleft%20%28%2033%2FRe%20%5Cright%20%29%5Cleft%20%28%20%5Cfrac%7BA_%7B_%7B0%7D%7D%7D%7BA_%7B_%7B1%7D%7D%7D%20%5Cright%20%29%5E%7B2%7D&bg=ffffff&fg=000000&s=0' alt='Latex formula' title='Latex formula' class='latex' \/><\/span>8<\/p>\n<p>where:<br \/>\n<span style=\"display: inline-block; width: 140px;\"><img src='http:\/\/s.wordpress.com\/latex.php?latex=%5Cdisplaystyle%20A_%7B0%7D&bg=ffffff&fg=000000&s=0' alt='Latex formula' title='Latex formula' class='latex' \/><\/span>is the total area of the ventilation<br \/>\n<span style=\"display: inline-block; width: 140px;\"><img src='http:\/\/s.wordpress.com\/latex.php?latex=%5Cdisplaystyle%20A_%7B1%7D&bg=ffffff&fg=000000&s=0' alt='Latex formula' title='Latex formula' class='latex' \/><\/span>is the total open area formed by the ventilation holes<\/p>\n<p><span style=\"display: inline-block; width: 500px;\"><img src='http:\/\/s.wordpress.com\/latex.php?latex=%5Cdisplaystyle%20%5Cvarepsilon%3D0.145%2B0.108Re%5E%7B0.183%7D&bg=ffffff&fg=000000&s=0' alt='Latex formula' title='Latex formula' class='latex' \/><\/span>9<br \/>\n<span style=\"display: inline-block; width: 500px;\"><img src='http:\/\/s.wordpress.com\/latex.php?latex=%5Cdisplaystyle%20%5Cvarphi%20%3D3.36%5Cleft%20%28%20%5Cfrac%7B5.56%7D%7BRe%7D%20%5Cright%20%29%5E%7B%280.367%2B1.57%28%5Cfrac%7BA_%7B1%7D%7D%7BA_%7B0%7D%7D%29%5E%7B2%7D%29%7D&bg=ffffff&fg=000000&s=0' alt='Latex formula' title='Latex formula' class='latex' \/><\/span>10<\/p>\n<p><span style=\"display: inline-block; width: 500px;\"><img src='http:\/\/s.wordpress.com\/latex.php?latex=%5Cdisplaystyle%20Re%3DUd_%7Bh%7D%2F%5Cnu&bg=ffffff&fg=000000&s=0' alt='Latex formula' title='Latex formula' class='latex' \/><\/span>11<br \/>\n<span style=\"display: inline-block; width: 140px;\"><img src='http:\/\/s.wordpress.com\/latex.php?latex=%5Cdisplaystyle%20%5Cnu&bg=ffffff&fg=000000&s=0' alt='Latex formula' title='Latex formula' class='latex' \/><\/span>is the kinematic viscosity of air<br \/>\n<span style=\"display: inline-block; width: 500px;\"><img src='http:\/\/s.wordpress.com\/latex.php?latex=%5Cdisplaystyle%20d_%7Bh%7D%3D4A%2Fc&bg=ffffff&fg=000000&s=0' alt='Latex formula' title='Latex formula' class='latex' \/><\/span>12<br \/>\n<span style=\"display: inline-block; width: 140px;\"><img src='http:\/\/s.wordpress.com\/latex.php?latex=%5Cdisplaystyle%20A&bg=ffffff&fg=000000&s=0' alt='Latex formula' title='Latex formula' class='latex' \/><\/span>is the area of a single ventilation opening<br \/>\n<span style=\"display: inline-block; width: 140px;\"><img src='http:\/\/s.wordpress.com\/latex.php?latex=%5Cdisplaystyle%20c&bg=ffffff&fg=000000&s=0' alt='Latex formula' title='Latex formula' class='latex' \/><\/span>is the perimeter of a single ventilation opening<\/p>\n<p>Note: <img src='http:\/\/s.wordpress.com\/latex.php?latex=d_%7Bh%7D&bg=FFFFFF&fg=000000&s=0' alt='Latex formula' title='Latex formula' class='latex' \/> can be calculated for openings of arbitrary shape. For circular openings <img src='http:\/\/s.wordpress.com\/latex.php?latex=d_%7Bh%7D%3D&bg=FFFFFF&fg=000000&s=0' alt='Latex formula' title='Latex formula' class='latex' \/> the diameter of the circle.<\/p>\n<p>Assuming the heat generated by the components is uniformly distributed, equation 13 can be used to relate the heat transferred to the air inside the enclosure via convection Q<sub>conv<\/sub> to the temperature difference of the air leaving and entering the enclosure through the ventilation openings.<\/p>\n<p><span style=\"display: inline-block; width: 500px;\"><img src='http:\/\/s.wordpress.com\/latex.php?latex=%5Cdisplaystyle%20Q_%7Bconv%7D%3D%5Crho%20_%7B%5Cinfty%20%7D%5Cdot%7BV%7Dc_%7Bp%7D%28T_%7Bout%7D-T_%7B%5Cinfty%20%7D%29&bg=ffffff&fg=000000&s=0' alt='Latex formula' title='Latex formula' class='latex' \/><\/span>13<\/p>\n<p>where:<br \/>\n<span style=\"display: inline-block; width: 140px;\"><img src='http:\/\/s.wordpress.com\/latex.php?latex=%5Cdisplaystyle%20%5Cdot%7BV%7D&bg=ffffff&fg=000000&s=0' alt='Latex formula' title='Latex formula' class='latex' \/><\/span>is the volumetric flow rate of air passing through the enclosure<br \/>\n<span style=\"display: inline-block; width: 140px;\"><img src='http:\/\/s.wordpress.com\/latex.php?latex=%5Cdisplaystyle%20c_%7Bp%7D&bg=ffffff&fg=000000&s=0' alt='Latex formula' title='Latex formula' class='latex' \/><\/span>is the specific heat of air at constant pressure<br \/>\n<span style=\"display: inline-block; width: 140px;\"><img src='http:\/\/s.wordpress.com\/latex.php?latex=%5Cdisplaystyle%20T_%7Bout%7D&bg=ffffff&fg=000000&s=0' alt='Latex formula' title='Latex formula' class='latex' \/><\/span>is the temperature of the air exiting the enclosure<\/p>\n<p>With the assumption that the heat generating components are distributed uniformly in the enclosure the temperature of the air increases linearly in the vertical direction through the enclosure. The average air temperature can then be calculated with equation 14.<\/p>\n<p><span style=\"display: inline-block; width: 500px;\"><img src='http:\/\/s.wordpress.com\/latex.php?latex=%5Cdisplaystyle%20%5Coverline%7BT%7D_%7Bint%7D%3D%5Cfrac%7BT_%7Bout%7D%2BT_%7B%5Cinfty%7D%7D%7B2%7D&bg=ffffff&fg=000000&s=0' alt='Latex formula' title='Latex formula' class='latex' \/><\/span>14<\/p>\n<p>Substituting the average internal air temperature with equation 14 in equation 4 and combining that with equation 13 results in equation 15, a new expression for the buoyancy pressure drop.<\/p>\n<p><span style=\"display: inline-block; width: 500px;\"><img src='http:\/\/s.wordpress.com\/latex.php?latex=%5Cdisplaystyle%20%5CDelta%20P_%7Bbouyancy%7D%3D%5Cfrac%7Bgh%5Cbeta%20Q_%7Bconv%7D%7D%7B2c_%7Bp%7D%5Cdot%7BV%7D%7D&bg=ffffff&fg=000000&s=0' alt='Latex formula' title='Latex formula' class='latex' \/><\/span>15<\/p>\n<p>The volumetric flow rate is used to calculate the speed of air through each ventilation opening using equation 16.<\/p>\n<p><span style=\"display: inline-block; width: 500px;\"><img src='http:\/\/s.wordpress.com\/latex.php?latex=%5Cdisplaystyle%20U%3D%5Cdot%7BV%7D%2FA_%7B1%7D&bg=ffffff&fg=000000&s=0' alt='Latex formula' title='Latex formula' class='latex' \/><\/span>16<\/p>\n<p>In most electronics applications the pressure drop due to the ventilation openings is much larger than that due to the internal electronic components since they are not densely packed. As such \u0394P<sub>comp<\/sub> can be ignored for most applications. Combining equations 5 and 16 and substituting the new values of inlet\/outlet pressure drops and buoyancy pressure difference from equation 15 into equation 1 gives equation 17. This equation has only one unknown, the volumetric flow rate of the air flowing through the enclosure since \u0394P<sub>comp<\/sub> is assumed too small for consideration.<\/p>\n<p><span style=\"display: inline-block; width: 500px;\"><img src='http:\/\/s.wordpress.com\/latex.php?latex=%5Cdisplaystyle%20%5Crho_%7B%5Cinfty%7D%5Cfrac%7BU_%7Binlet%7D%5E%7B2%7D%7D%7B2%7Dk_%7Binlet%7D%2B%5Crho_%7B%5Cinfty%7D%5Cfrac%7BU_%7Boutlet%7D%5E%7B2%7D%7D%7B2%7Dk_%7Boutlet%7D-%5Cfrac%7Bgh%5Cbeta%20Q_%7Bconv%7D%7D%7B2c_%7Bp%7D%5Cdot%7BV%7D%7D%3D0&bg=ffffff&fg=000000&s=0' alt='Latex formula' title='Latex formula' class='latex' \/><\/span>17<\/p>\n<p>The variables with the subscripts inlet and outlet reference the corresponding variable values for the inlet and outlet ventilation openings. The value of the volumetric flow rate can be calculated using an equation solving function available in most mathematics software or using the goal seek function in MS Excel.<\/p>\n<p>Because there is a linear increase in the temperature of the air along the height of the enclosure equation 18 can be used to determine the air temperature as a function of the height location in the enclosure.<\/p>\n<p><span style=\"display: inline-block; width: 500px;\"><img src='http:\/\/s.wordpress.com\/latex.php?latex=%5Cdisplaystyle%20T%28x%29%3D%5Cfrac%7BQ_%7Bconv%7Dx%7D%7Bhc_%7Bp%7D%5Cdot%7BV%7D%5Crho%20_%7B%5Cinfty%7D%7D%2BT_%7B%5Cinfty%20%7D&bg=ffffff&fg=000000&s=0' alt='Latex formula' title='Latex formula' class='latex' \/><\/span>18<\/p>\n<p>Note that the total heat loss from the components is equal to the sum of the heat losses due to convection Q<sub>conv<\/sub> and radiation Q<sub>rad<\/sub>. A conservative approach is to assume all the losses are due to convection. However if the component temperatures are high and the ventilation openings are small then radiation may account for 30% or more of the total heat losses.<\/p>\n<p><a href=\"https:\/\/www.heatsinkcalculator.com\/enclosure_temperature_rise_calculator.html\" target=\"_blank\" rel=\"noopener\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-1179 size-full\" src=\"http:\/\/www.heatsinkcalculator.com\/blog\/wp-content\/uploads\/2017\/07\/Enclosure_Temperature_Rise_Calculator_Ad-0.1.png\" alt=\"Enclosure temperature rise calculator\" width=\"544\" height=\"647\" srcset=\"https:\/\/www.heatsinkcalculator.com\/blog\/wp-content\/uploads\/2017\/07\/Enclosure_Temperature_Rise_Calculator_Ad-0.1.png 544w, https:\/\/www.heatsinkcalculator.com\/blog\/wp-content\/uploads\/2017\/07\/Enclosure_Temperature_Rise_Calculator_Ad-0.1-252x300.png 252w\" sizes=\"auto, (max-width: 544px) 100vw, 544px\" \/><\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Electrical and electronic components are sometimes housed in enclosures with ventilation openings to allow ambient air into the enclosure to [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[1],"tags":[],"class_list":["post-737","post","type-post","status-publish","format-standard","hentry","category-uncategorized"],"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/www.heatsinkcalculator.com\/blog\/wp-json\/wp\/v2\/posts\/737","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.heatsinkcalculator.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.heatsinkcalculator.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.heatsinkcalculator.com\/blog\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.heatsinkcalculator.com\/blog\/wp-json\/wp\/v2\/comments?post=737"}],"version-history":[{"count":80,"href":"https:\/\/www.heatsinkcalculator.com\/blog\/wp-json\/wp\/v2\/posts\/737\/revisions"}],"predecessor-version":[{"id":1185,"href":"https:\/\/www.heatsinkcalculator.com\/blog\/wp-json\/wp\/v2\/posts\/737\/revisions\/1185"}],"wp:attachment":[{"href":"https:\/\/www.heatsinkcalculator.com\/blog\/wp-json\/wp\/v2\/media?parent=737"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.heatsinkcalculator.com\/blog\/wp-json\/wp\/v2\/categories?post=737"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.heatsinkcalculator.com\/blog\/wp-json\/wp\/v2\/tags?post=737"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}